You are here

CMC database

Field of measurement: flow
Quantity: mass gas flow rate
Internal identifier Range Calibration and measurement capabilities Procedure Note to procedure
3.5 (0,06 - 1200) m3/h 0.25 % MH 512-MP-C103
3.5 (20 - 1.0E+4) m3/h 0.19 % MH 512-MP-C103
3.5 (0,3 - 1600) m3/h 0.2 % MH 512-MP-C103
3.5 (0,02 - 16) m3/h 512-MP-C103
3.5 (Qmin - 0,1Qmax) 0.65 % MH 512-MP-C103
3.5 (0,1Qmax - Qmax) 0.28 % MH 512-MP-C103
3.5 (0,02 - 160) m3/h 512-MP-C103
3.5 (Qmin - 0,1Qmax) 0.7 % MH 512-MP-C103
3.5 (0,1Qmax - Qmax) 0.5 % MH 512-MP-C103
3.5 (9,5 - 760) m3/h 0.16 % MH 512-MP-C103
3.6 (0,01 - 0,75) m3/h 1 % MH 512-MP-C104
3.6 (0,75 - 1,3) m3/h 1.3 % MH 512-MP-C104
3.6 (1,3 - 25) m3/h 1 % MH 512-MP-C104
Quantity: teplota
Internal identifier Range Calibration and measurement capabilities Procedure Note to procedure
3.7 (-30 - 80) °C 0.06 % MH přepočítávacího čísla Z 512-MP-C105
Field of measurement: thermometry and humidity
Quantity: teplota
Internal identifier Range Calibration and measurement capabilities Conditions of measurement Procedure Note to procedure
1 (-90 - 100) °C 0.015 °C
  • dělení < 0.1 °C
133-MP-C001
1 (100 - 150) °C 0.02 °C
  • dělení < 0.1 °C
133-MP-C001
1 (150 - 210) °C 0.04 °C
  • dělení < 0.1 °C
133-MP-C001
1 (210 - 360) °C 0.05 °C
  • dělení < 0.1 °C
133-MP-C001
1 (360 - 420) °C 0.15 °C
  • dělení 0,1 °C ≤ division < 1 °C
133-MP-C001
1 (420 - 550) °C 0.2 °C
  • dělení 0,1 °C ≤ division < 1 °C
133-MP-C001
4 (0.01 - 0.01) °C 0.002 °C 133-MP-C004
4 (660.3 - 660.3) °C 0.05 °C 133-MP-C004
4 (-196 - -196) °C 0.03 °C 133-MP-C004
4 (-196 - -100) °C 0.3 °C 133-MP-C004
4 (-100 - -90) °C 0.2 °C 133-MP-C004
4 (-90 - -80) °C 0.015 °C 133-MP-C004
4 (-80 - 160) °C 0.01 °C 133-MP-C004
4 (160 - 300) °C 0.02 °C 133-MP-C004
4 (300 - 420) °C 0.03 °C 133-MP-C004
4 (420 - 550) °C 0.05 °C 133-MP-C004
4 (550 - 660) °C 0.09 °C 133-MP-C004
4 (660 - 1100) °C 0.8 °C 133-MP-C004
4 (1100 - 1300) °C 1.3 °C 133-MP-C004
4 (1300 - 1600) °C 2.1 °C 133-MP-C004
Field of measurement: volume
Quantity: volume of liquids
Internal identifier Range Calibration and measurement capabilities Conditions of measurement Procedure Note to procedure
CZ17 (0,02 - 100) L 0,01 %
  • liquid  water
  • reference temperature 20°C
532-MP-C302
CZ18 (0,5 - 2000) mL 0,05 %
  • liquid  water
  • reference temperature 20°C
532-MP-C301
CZ19 (0,002 - 5000) mL 2,00 %
  • liquid  water
  • reference temperature 20°C
532-MP-C303
3.1 (0,2 - 0,5) cm3 0.00014 cm3
  • liquid  water
  • reference temperature 20°C
532-MP-C301
3.1 (> 0,5 - 5) cm3 0.00015 cm3
  • liquid  water
  • reference temperature 20°C
532-MP-C301
3.1 (> 5 - 10) cm3 0.00016 cm3
  • liquid  water
  • reference temperature 20°C
532-MP-C301
3.1 (> 10 - 25) cm3 0.00018 cm3
  • liquid  water
  • reference temperature 20°C
532-MP-C301
3.1 (> 25 - 50) cm3 0.00024 cm3
  • liquid  water
  • reference temperature 20°C
532-MP-C301
3.1 (> 50 - 100) cm3 0.00039 cm3
  • liquid  water
  • reference temperature 20°C
532-MP-C301
3.1 (> 100 - 200) cm3 0.00087 cm3
  • liquid  water
  • reference temperature 20°C
532-MP-C301
3.1 (> 200 - 250) cm3 0.0011 cm3
  • liquid  water
  • reference temperature 20°C
532-MP-C301
3.1 (> 250 - 500) cm3 0.0041 cm3
  • liquid  water
  • reference temperature 20°C
532-MP-C301
3.1 (> 500 - 1000) cm3 0.0054 cm3
  • liquid  water
  • reference temperature 20°C
532-MP-C301
3.1 (> 1000 - 2000) cm3 0.0093 cm3
  • liquid  water
  • reference temperature 20°C
532-MP-C301
3.1 (> 2000 - 5000) cm3 0.021 cm3
  • liquid  water
  • reference temperature 20°C
532-MP-C301
3.1 (> 5000 - 1.0E+4) cm3 0.29 cm3
  • liquid  water
  • reference temperature 20°C
532-MP-C301