You are here

Calibration and measurement capabilities

photometry and radiometry
Interní identifikátor Quantity Calibration and measurement capabilities Measurement conditions Note Technical competence Link
Luminous intensity
  • 1 cd - 10000 cd

     

    0.9 - 0.8 %

  • Correlated colour temperature (2000 up to 2856) K
varies with colour temperature CIPM MRA
Luminous intensity
  • 1 cd - 10000 cd

     

    0.8 - 0.9 %

  • Correlated color temperature (2856 up to 3200) K
varies with colour temperature CIPM MRA
Illuminance responsivity, tungsten source
  • - A/lx - - A/lx

     

    0.9 - 0.8 %

  • Illuminance (0.1 up to 10) lx
  • Correlated colour temperature 2856 K
varies with illuminance CIPM MRA
Illuminance responsivity, tungsten source
  • - A/lx - - A/lx

     

    0.8 %

  • Illuminance (10 up to 1000) lx
  • Correlated colour temperature 2856 K
CIPM MRA
Illuminance responsivity, tungsten source
  • - A/lx - - A/lx

     

    0,8 - 1,2 %

  • Illuminance (1000 up to 30000) lx
  • Correlated colour temperature 2856 K
varies with illuminance CIPM MRA
Luminous flux
  • 10 lm - 30000 lm

     

    0,9 - 1,5 %

  • Correlated colour temperature (2000 up to 3200) K
varies with measurand and colour temperature CIPM MRA
Illuminance
  • 0.1 lx - 10 lx

     

    0,9 - 0,8 %

  • Correlated colour temperature (2000 up to 3200) K
varies with measurand CIPM MRA
Illuminance
  • 10 lx - 1000 lx

     

    0,8 %

  • Correlated colour temperature (2000 up to 3200) K
CIPM MRA
Illuminance
  • 1000 lx - 30000 lx

     

    0,8 - 1,2 %

  • Correlated colour temperature (2000 up to 3200) K
varies with measurand CIPM MRA
Spectral responsivity, power
  • Wavelength range (300 up to 405) nm
  • Bandwidth < 10 nm
  • Power level < 30 µW
CIPM MRA
Spectral responsivity, power
  • Wavelength range (405 up to 920) nm
  • Bandwidth < 10 nm
  • Power level < 30 µW
CIPM MRA
Spectral responsivity, power
  • Wavelength range (920 up to 960) nm
  • Bandwidth < 10 nm
  • Power level < 30 µW
CIPM MRA
Spectral responsivity, power
  • Wavelength range (960 up to 1000) nm
  • Bandwidth < 10 nm
  • Power level < 30 µW
CIPM MRA
Responsivity, spectrum, irradiance
  • Wavelength (300 up to 405) nm
  • Bandwidth < 10 nm
  • Power level < 30 µW
CIPM MRA
Responsivity, spectrum, irradiance
  • Wavelength (405 up to 920) nm
  • Bandwidth < 10 nm
  • Power level < 30 µW
CIPM MRA
Responsivity, spectrum, irradiance
  • Wavelength (920 up to 960) nm
  • Bandwidth < 10 nm
  • Power level < 30 mW
CIPM MRA
Responsivity, spectrum, irradiance
  • Wavelength (960 up to 1000) nm
  • Bandwidth < 10 nm
  • Power level < 30 mW
CIPM MRA
Responsivity laser, power
  • Wavelength range (356 up to 413) nm
  • Power level < 1 mW
CIPM MRA
Responsivity laser, power
  • Wavelength range (476 up to 799) nm
  • Power level < 1 mW
CIPM MRA
Responsivity, UV, broadband irradiance
  • Wavelength UV-A
  • Type of source Hg discharge lamp, LED source
  • Irradiance level < 10 mW/cm2
CIPM MRA
Responsivity, UV, broadband radiant exposure
  • Wavelength UV-A
  • Type of source Hg discharge lamp, LED source
  • Irradiance level < 10 mW/cm2
CIPM MRA
Transmittance, regular spectral
  • 0.65  - 1 

     

    0,0008

  • Wavelength (380 up to 1000) nm
  • Bandwidth < 3 nm
CIPM MRA
Transmittance, regular spectral
  • 0.3  - 0.65 

     

    0,0041

  • Wavelength (380 up to 400) nm
  • Bandwidth < 3 nm
CIPM MRA
Transmittance, regular spectral
  • 0.3  - 0.65 

     

    0,0013

  • Wavelength (400 up to 700) nm
  • Bandwidth < 3 nm
CIPM MRA
Transmittance, regular spectral
  • 0.3  - 0.65 

     

    0,0017

  • Wavelength (700 up to 1000) nm
  • Bandwidth < 3 nm
CIPM MRA
Transmittance, regular spectral
  • 0.02  - 0.3 

     

    0,0015

  • Wavelength (380 up to 400) nm
  • Bandwidth < 3 nm
CIPM MRA
Transmittance, regular spectral
  • 0.02  - 0.3 

     

    0,00022

  • Wavelength (400 up to 1000) nm
  • Bandwidth < 3 nm
CIPM MRA
Absorbance, regular, spectral
  • 0  - 0.19 

     

    0.0003 - 5.0E-5

  • Wavelength (380 up to 1000) nm
  • Bandwidth < 3 nm
varies with measurand CIPM MRA
Absorbance, regular, spectral
  • 0.19  - 0.52 

     

    0.0019 - 0.0052

  • Wavelength (380 up to 400) nm
  • Bandwidth < 3 nm
varies with measurand CIPM MRA
Absorbance, regular, spectral
  • 0.19  - 0.52 

     

    0.0009 - 0.0019

  • Wavelength (400 up to 700) nm
  • Bandwidth < 3 nm
varies with measurand CIPM MRA
Absorbance, regular, spectral
  • 0.19  - 0.52 

     

    0.0011 - 0.0025

  • Wavelength (700 up to 1000) nm
  • Bandwidth < 3 nm
varies with measurand CIPM MRA
Absorbance, regular, spectral
  • 0.52  - 1.7 

     

    0.0022 - 0.0339

  • Wavelength (380 up to 400) nm
  • Bandwidth < 3 nm
varies with measurand CIPM MRA
Absorbance, regular, spectral
  • 0.52  - 1.7 

     

    0.0003 - 0.0048

  • Wavelength (400 up to 1000) nm
  • Bandwidth < 3 nm
varies with measurand CIPM MRA
Absorbance, regular, spectral
  • 1.7  - 3 

     

    0.03 - 0.0969

  • Wavelength (380 up to 400) nm
  • Bandwidth < 3 nm
varies with measurand CIPM MRA
Absorbance, regular, spectral
  • 1.7  - 3 

     

    0.0017 - 0.0362

  • Wavelength (400 up to 1000) nm
  • Bandwidth < 3 nm
varies with measurand CIPM MRA
Wavelength
  • 400 nm - 1650 nm

     

    2.0E-6 (bezrozměrný)

  • CW Single frequency, Power level ˃ 0,05 mW
CIPM MRA
Wavelength
  • 400 nm - 1650 nm

     

    1.0E-7 (bezrozměrný)

  • CW Single frequency, Power level ˃ 0,05 mW
CIPM MRA
Wavelength
  • 400 nm - 1650 nm

     

    1.0E-7 (bezrozměrný)

  • CW Single frequency, Power level ˃ 0,05 mW
CIPM MRA
Responsivity, spectrum, irradiance
  • Wavelength 1000 nm upt to 1580 nm
  • Bandwidth < 10 nm
  • Power level < 30 µW
CIPM MRA
Responsivity, spectrum, irradiance
  • Wavelength (1580 up to 1580) nm
  • Bandwidth < 10 nm
  • Power level < 30 µW
CIPM MRA
Spectral responsivity, power
  • Wavelength range (900 up to 950) nm
  • Bandwidth < 10 nm
  • Power level < 30 µW
CIPM MRA
Spectral responsivity, power
  • Wavelength range (1000 up to 1400) nm
  • Bandwidth < 10 nm
  • Power level < 30 µW
CIPM MRA
Spectral responsivity, power
  • Wavelength range (1410 up to 1525) nm
  • Bandwidth < 10 nm
  • Power level < 30 µW
CIPM MRA
Spectral responsivity, power
  • Wavelength range (1550 up to 1600) nm
  • Bandwidth < 10 nm
  • Power level < 30 µW
CIPM MRA
Spectral responsivity, power
  • Wavelength range (950 up to 1000) nm
  • Bandwidth < 10 nm
  • Power level < 30 µW
CIPM MRA
Spectral responsivity, power
  • Wavelength range (1525 up to 1550) nm
  • Bandwidth < 10 nm
  • Power level < 30 µW
CIPM MRA
Spectral responsivity, power
  • Wavelength range (1400 up to 1410) nm
  • Bandwidth < 10 nm
  • Power level < 30 µW
CIPM MRA
1 Spectral reflectance factor R
  • 0 % - 100 %

     

    (0,1 + 0,010R) % (abs.)

  • Wavelength (380 up to 460) nm
  • geometry 8º / t, 8º / d
internal metrology service accreditation
1 Spectral reflectance factor R
  • 0 % - 100 %

     

    (0,12 + 0,008R) % (abs.)

  • Wavelength 465 up to 780 nm
  • geometry 8º / t, 8º / d
internal metrology service accreditation
1 Spectral reflectance factor R
  • 0 % - 100 %

     

    (0,17 + 0,014R) % (abs.)

  • Wavelength (380 up to 780) nm
  • geometry 0º / 45º
internal metrology service accreditation
1 Spectral reflectance factor R
  • 0 % - 100 %

     

    (0,1 + 0,010R) % (abs.)

  • Wavelength (380 up to 460) nm
  • geometry 8º / t, 8º / d
internal metrology service accreditation
1 Spectral reflectance factor R
  • 0 % - 100 %

     

    (0,12 + 0,008R) % (abs.)

  • Wavelength 465 up to 780 nm
  • geometry 8º / t, 8º / d
internal metrology service accreditation
1 Spectral reflectance factor R
  • 0 % - 100 %

     

    (0,17 + 0,014R) % (abs.)

  • Wavelength (380 up to 780) nm
  • geometry 0º / 45º
internal metrology service accreditation
2 Surface colour, colorimetric coordinate L*
  • 2  - 99 

     

    0.35 % (abs.)

  • -110  - 110 

     

    0.25 % (abs.)

  • geometry 8º / t, 8º / d, 0º / 45º
internal metrology service accreditation
2 Surface colour, colorimetric coordinate L*
  • 2  - 99 

     

    0.4 % (abs.)

  • -110  - 110 

     

    0.3 % (abs.)

  • geometry 8º / t, 8º / d, 0º / 45º
internal metrology service accreditation
3 Surface colour, colorimetric coordinate Y
  • 0.3  - 100 

     

    0.25 % (abs.)

  • 0.002  - 0.7 

     

    0.0005 % (abs.)

  • 0.002  - 0.8 

     

    0.0005 % (abs.)

  • geometry 8º / t, 8º / d, 0º / 45º
internal metrology service accreditation
3 Surface colour, colorimetric coordinate Y
  • 0.3  - 100 

     

    0.35 % (abs.)

  • 0.002  - 0.7 

     

    0.0007 % (abs.)

  • 0.002  - 0.8 

     

    0.0007 % (abs.)

  • geometry 8º / t, 8º / d, 0º / 45º
internal metrology service accreditation
4 Surface colour, colorimetric coordinate L
  • 2  - 99 

     

    0.35 % (abs.)

  • 0.002  - 0.6 

     

    0.0005 % (abs.)

  • geometry 8º / t, 8º / d, 0º / 45º
internal metrology service accreditation
4 Surface colour, colorimetric coordinate L
  • 2  - 99 

     

    0.4 - 0.35 % (abs.)

  • 0.002  - 0.6 

     

    0.0008 % (abs.)

  • geometry 8º / t, 8º / d, 0º / 45º
internal metrology service accreditation
5 Gloss
  • 0.1 GU - 150 GU

     

    1.8 GU

  • geometry 20º, 60º, 85º
accreditation
6 Illuminance
  • 5 lx - 50000 lx

     

    2.2 %

internal and external metrology service accreditation
6 Illuminance
  • 1 lx - 50000 lx

     

    0.8 %

internal and external metrology service accreditation
7 Irradiance
  • 0.0001 mW/cm2 - 1000 mW/cm2

     

    5 %

  • Wavelength (230 up to 470) nm
internal and external metrology service accreditation
8 Correlated colour temperature
  • 2000 K - 10000 K

     

    10 - 85 K

internal and external metrology service accreditation
9 Perpendicular spectral transmittance
  • 0.1  - 1 

     

    0.0012

  • Wavelength (200 up to 380) nm
internal and external metrology service accreditation
9 Perpendicular spectral transmittance
  • 0.001  - 0.1 

     

    0.0001

  • Wavelength (200 up to 380) nm
internal and external metrology service accreditation
9 Perpendicular spectral transmittance
  • 0.6  - 1 

     

    0.0008

  • Wavelength (380 up to 1000) nm
internal and external metrology service accreditation
9 Perpendicular spectral transmittance
  • 0.3  - 0.6 

     

    0.0041

  • Wavelength (380 up to 400) nm
internal and external metrology service accreditation
9 Perpendicular spectral transmittance
  • 0.3  - 0.6 

     

    0.00056

  • Wavelength (400 up to 700) nm
internal and external metrology service accreditation
9 Perpendicular spectral transmittance
  • 0.3  - 0.6 

     

    0.0017

  • Wavelength (700 up to 1000) nm
internal and external metrology service accreditation
9 Perpendicular spectral transmittance
  • 0.02  - 0.3 

     

    0.0015

  • Wavelength (380 up to 400) nm
internal and external metrology service accreditation
9 Perpendicular spectral transmittance
  • 0.02  - 0.3 

     

    0.00022

  • Wavelength (400 up to 1000) nm
internal and external metrology service accreditation
9 Perpendicular spectral transmittance
  • 0.001  - 0.02 

     

    0.0002

  • Wavelength (380 up to 400) nm
internal and external metrology service accreditation
9 Perpendicular spectral transmittance
  • 0.001  - 0.02 

     

    8.000000000000001E-5

  • Wavelength (400 up to 1000) nm
internal and external metrology service accreditation
10 kolmá spektrální absorbance
  • 0  - 1 

     

    0.0005 - 0.0052 (abs.)

  • Wavelength (200 up to 380) nm
internal and external metrology service accreditation
10 kolmá spektrální absorbance
  • 1  - 3 

     

    0.0004 - 0.046 (abs.)

  • Wavelength (200 up to 380) nm
internal and external metrology service accreditation
10 kolmá spektrální absorbance
  • 0  - =-LOG10(H157) 

     

    0.0003 - 0.0005999999999999999 (abs.)

  • Wavelength (380 up to 1000) nm
internal and external metrology service accreditation
10 kolmá spektrální absorbance
  • 0.22  - 0.52 

     

    0.003 - 0.006 (abs.)

  • Wavelength (380 up to 400) nm
internal and external metrology service accreditation
10 kolmá spektrální absorbance
  • 0.22  - 0.52 

     

    0.0004 - 0.0008 (abs.)

  • Wavelength (400 up to 700) nm
internal and external metrology service accreditation
10 kolmá spektrální absorbance
  • 0.22  - 0.52 

     

    0.0012 - 0.0025 (abs.)

  • Wavelength (700 up to 1000) nm
internal and external metrology service accreditation
10 kolmá spektrální absorbance
  • 0.52  - 1.7 

     

    0.0022 - 0.034 (abs.)

  • Wavelength (380 up to 400) nm
internal and external metrology service accreditation
10 kolmá spektrální absorbance
  • 0.52  - 1.7 

     

    0.0003 - 0.0048 (abs.)

  • Wavelength (400 up to 1000) nm
internal and external metrology service accreditation
10 kolmá spektrální absorbance
  • 1.7  - 3 

     

    0.0044 - 0.097 (abs.)

  • Wavelength (380 up to 400) nm
internal and external metrology service accreditation
10 kolmá spektrální absorbance
  • 1.7  - 3 

     

    0.0017 - 0.036 (abs.)

  • Wavelength (400 up to 1000) nm
internal and external metrology service accreditation
11 Wavelength
  • 200 nm - 1700 nm

     

    0.2 nm

internal and external metrology service accreditation
11 Wavelength
  • 200 nm - 1700 nm

     

    0.2 nm

internal and external metrology service accreditation
12 Optical density D
  • 0  - 4.5 

     

    3.8 (abs.)

internal metrology service accreditation
12 Optical density D
  • 0  - 4.5 

     

    3.8 (abs.)

internal metrology service accreditation
13 Optical power
  • 1.0E-9 W - 10 W

     

    0.4 %

  • Wavelength (800 up to 920) nm
internal metrology service accreditation
13 Optical power
  • 1.0E-9 W - 10 W

     

    0.5 %

  • Wavelength (920 up to 960) nm
internal metrology service accreditation
13 Optical power
  • 1.0E-9 W - 10 W

     

    0.45 %

  • Wavelength (960 up to 1000) nm
internal metrology service accreditation
13 Optical power
  • 1.0E-9 W - 10 W

     

    0.47 %

  • Wavelength (1000 up to 1580) nm
internal metrology service accreditation
13 Optical power
  • 1.0E-9 W - 10 W

     

    0.6 %

  • Wavelength (1580 up to 1650) nm
internal metrology service accreditation
14 Optical attenuation
  • 0 dB - 65 dB

     

    0.052 dB (abs.)

  • Wavelength (800 up to 1650) nm
internal metrology service accreditation
15 Linearity
  • 0 dB - 0.5 dB

     

    0.004 dB

  • Power level 0 DBm up to 65 dBm
  • Wavelength (800 up to 1650) nm
internal metrology service accreditation
16 Wavelength
  • 800 nm - 1650 nm

     

    4.0E-9 nm

internal metrology service accreditation
17 Luminous intensity
  • 1 cd - 20000 cd

     

    0.8 %

internal metrology service accreditation
18 Brightness
  • 1 cd.m-2 - 30000 cd.m-2

     

    1.1 %

internal metrology service accreditation
19 Luminous flux
  • 10 lm - 20000 lm

     

    1 %

internal metrology service accreditation
20 Spectral irradiance
  • 0.65 nW.m-2.nm-1 - 300 nW.m-2.nm-1

     

    3.4 %

  • Wavelength (300 up to 400) nm
internal metrology service accreditation
20 Spectral irradiance
  • 0.65 nW.m-2.nm-1 - 300 nW.m-2.nm-1

     

    3 %

  • Wavelength (400 up to 1700) nm
internal metrology service accreditation
20 Spectral irradiance
  • 0.65 nW.m-2.nm-1 - 300 nW.m-2.nm-1

     

    4.5 %

  • Wavelength (1700 up to 2500) nm
internal metrology service accreditation
21 Spectral radiance
  • 1.12 nW.s-1.m-2.nm-1 - 10 nW.s-1.m-2.nm-1

     

    3.2 %

  • Wavelength (370 up to 800) nm
internal metrology service accreditation
21 Spectral radiance
  • 1.12 nW.s-1.m-2.nm-1 - 10 nW.s-1.m-2.nm-1

     

    3.6 %

  • Wavelength (800 up to 1000) nm
internal metrology service accreditation
21 Spectral radiance
  • 1.12 nW.s-1.m-2.nm-1 - 10 nW.s-1.m-2.nm-1

     

    3 %

  • Wavelength (1000 up to 1700) nm
internal metrology service accreditation
21 Spectral radiance
  • 1.5 nW.s-1.m-2.nm-1 - 95 nW.s-1.m-2.nm-1

     

    3.2 %

  • Wavelength (370 up to 800) nm
internal metrology service accreditation
21 Spectral radiance
  • 1.5 nW.s-1.m-2.nm-1 - 95 nW.s-1.m-2.nm-1

     

    3.6 %

  • Wavelength (800 up to 1000) nm
internal metrology service accreditation
21 Spectral radiance
  • 1.5 nW.s-1.m-2.nm-1 - 95 nW.s-1.m-2.nm-1

     

    3 %

  • Wavelength (1000 up to 1700) nm
internal metrology service accreditation
22 Wavelength
  • 365 nm - 923 nm

     

    0.4 nm

internal metrology service accreditation
23 Spectral integral parameters: substitute chromaticity temperature Tc
  • 2000 K - 10000 K

     

    20 K

internal metrology service accreditation
23 Spectral integral parameters: colour rendering index Ra
  • 1  - 100 

     

    1.2 (abs.)

internal metrology service accreditation
23 Spectral integral parameters: ligtht colour, colorimetric coordinate x
  • 0.002  - 0.7 

     

    0.0025 (abs.)

  • 0.002  - 0.8 

     

    0.002 (abs.)

internal metrology service accreditation
23 Spectral integral parameters: ligtht colour, colorimetric coordinate u´
  • 0.002  - 0.6 

     

    0.0017 (abs.)

  • 0.002  - 0.6 

     

    0.0015 (abs.)

internal metrology service accreditation
23 Spectral integral parameters: substitute chromaticity temperature Tc
  • 2000 K - 10000 K

     

    20 K

internal metrology service accreditation
23 Spectral integral parameters: colour rendering index Ra
  • 1  - 100 

     

    0.7 (abs.)

internal metrology service accreditation
23 Spectral integral parameters: ligtht colour, colorimetric coordinate x
  • 0.002  - 0.7 

     

    0.0014 (abs.)

  • 0.002  - 0.8 

     

    0.001 (abs.)

internal metrology service accreditation
23 Spectral integral parameters: ligtht colour, colorimetric coordinate u´
  • 0.002  - 0.6 

     

    0.0009 (abs.)

  • 0.002  - 0.6 

     

    0.0005999999999999999 (abs.)

internal metrology service accreditation