You are here

CMC database

Field of measurement: length
Quantity: central length
Internal identifier Range Calibration and measurement capabilities Procedure Note to procedure
1.13 (0 - 1020) mm U3: (0,6 + 0,8×L) µm 815-MP-C503
1.14 (0.3 - 30) m Q(100;3×L) µm 815-MP-C510
1.14 (0 - 300) m Q(20;20×L) µm 815-MP-C510
1.15 (0 - 1020) mm Q (0,2; 0,8×L) µm 815-MP-C511
1.20 (0 - 1800) mm 15 µm 815-MP-C502
1.20 (0 - 1800) mm 13 µm 815-MP-C502
Field of measurement: electricity and magnetism
Quantity: high DC voltage: meters
Internal identifier Range Calibration and measurement capabilities Conditions of measurement Procedure Note to procedure
HVC02 (1 - 100) kV (80 - 700) V
  • room temperature 23 °C
801-MP-C702
Quantity: high voltage impedance: capacitance
Internal identifier Range Calibration and measurement capabilities Conditions of measurement Procedure Note to procedure
HVC04a (10 - 1.0E+6) pF (250 - 250) µF/F
  • voltage 0,1 kV to 400 kV
  • frequency 50 Hz
801-MP-C703
Quantity: High voltage impedance: dissipation factor for capacitance
Internal identifier Range Calibration and measurement capabilities Conditions of measurement Procedure Note to procedure
HVC04b (5.0E-5 - 0.1) (3.0E-5 - 0.003)
  • voltage up to 400 kV
  • frequency 50 Hz
801-MP-C703
Quantity: voltage transformer: ratio error
Internal identifier Range Calibration and measurement capabilities Conditions of measurement Procedure Note to procedure
HVC11a (0 - 20) % (0.006 - 0.2) %
  • voltage ratio 100/5 V/V to 400/250 kV/V
  • frequency 50 Hz
817-MP-C701
Quantity: voltage transformer: phase displacement
Internal identifier Range Calibration and measurement capabilities Conditions of measurement Procedure Note to procedure
HVC11b (0 - 20) crad (0.006 - 0.2) crad
  • voltage ratio 100/5 V/V to 400/250 kV/V
  • frequency 50 Hz
817-MP-C701
Quantity: current transformer: ratio error
Internal identifier Range Calibration and measurement capabilities Conditions of measurement Procedure Note to procedure
HVC24a (0 - 20) % (0.002 - 0.2) %
  • current ratio 0.5/5 A/A to 5000/5 A/A and 5/1 A/A to 5000/1 A/A
  • frequency 50 Hz
817-MP-C701
Quantity: current transformer: phase displacement
Internal identifier Range Calibration and measurement capabilities Conditions of measurement Procedure Note to procedure
HVC24b (0 - 20) crad (0.002 - 0.2) crad
  • current ratio 0.5/5 A/A to 5000/5 A/A and 5/1 A/A to 5000/1 A/A
  • frequency 50 Hz
817-MP-C701
Quantity: phase angle: meters
Internal identifier Range Calibration and measurement capabilities Conditions of measurement Procedure Note to procedure
SIG04 (0 - 360) ° (0.01 - 0.5) °
  • frequency 1 Hz to 10 MHz
  • voltage 0.01 V to 100 V
817-MP-C701
Quantity: magnetic fields below 50 kHz: magnetic flux
Internal identifier Range Calibration and measurement capabilities Conditions of measurement Procedure Note to procedure
EMF03a (0.1 - 100) mWb (10 - 10) 0.001 817-MP-C610
EMF03b (2 - 100) mWb (0,24 - 1) 0.001
  • magnetic flux per unit current 1 mWb/A to 100 mWb/A
817-MP-C601
Quantity: magnetic fields below 50 kHz: DC magnetic flux density
Internal identifier Range Calibration and measurement capabilities Conditions of measurement Procedure Note to procedure
EMF04 (5.0E-5 - 2) T (5 - 5) 0.001
  • homogeneity of magnetic flux density 0 %/cm to 0.01 %/cm
817-MP-C609
Quantity: magnetic fields below 50 kHz: AC magnetic flux density
Internal identifier Range Calibration and measurement capabilities Conditions of measurement Procedure Note to procedure
EMF05 (0.005 - 10) mT (6 - 15) 0.001
  • frequency 10 Hz to 50 kHz
817-MP-C608
Quantity: magnetic fields below 50 kHz: turn area
Internal identifier Range Calibration and measurement capabilities Conditions of measurement Procedure Note to procedure
EMF08a (0.01 - 10) Wb/T (2 - 2) 0.001
  • magnetic flux 1 mWb to 100 mWb
817-MP-C603
EMF08b (0.01 - 1) Wb/T (5 - 5) 0.001
  • frequency 40 Hz to 1000 Hz
817-MP-C603
Quantity: magnetic fields below 50 kHz: DC magnetic flux density per unit current
Internal identifier Range Calibration and measurement capabilities Conditions of measurement Procedure Note to procedure
EMF09a (0.5 - 50) mT/A (0,07 - 0,1) 0.001
  • magnetic flux density 0.5 mT to 100 mT
817-MP-C602
Quantity: magnetic fields below 50 kHz: AC magnetic flux density per unit current
Internal identifier Range Calibration and measurement capabilities Conditions of measurement Procedure Note to procedure
EMF09b (0.05 - 10) mT/A (0,6 - 5) 0.001
  • frequency 40 Hz to 20000 Hz
817-MP-C603
Quantity: Soft magnetic sheet and powder materials: specific total power loss
Internal identifier Range Calibration and measurement capabilities Conditions of measurement Procedure Note to procedure
MAT06 (0.2 - 20) W/kg (5 - 5) 0.001
  • frequency 50 Hz to 60 Hz
  • polarisation 0,3 T to 1,7 T
817-MP-C604
Quantity: Soft magnetic sheet and powder materials: peak value of AC magnetic polarisation
Internal identifier Range Calibration and measurement capabilities Conditions of measurement Procedure Note to procedure
MAT08 (0.1 - 1.9) T (5 - 5) 0.001
  • frequency 50 Hz
817-MP-C604
Quantity: Soft magnetic sheet and powder materials: peak value of magnetic field strength
Internal identifier Range Calibration and measurement capabilities Conditions of measurement Procedure Note to procedure
MAT09 (0.03 - 10) kA/m (5 - 5) 0.001
  • frequency 50 Hz
  • polarisation 0,1 T to 1,9 T
817-MP-C604
Quantity: Soft magnetic sheet and powder materials: RMS value of magnetic field strength
Internal identifier Range Calibration and measurement capabilities Conditions of measurement Procedure Note to procedure
MAT10 (0.03 - 10) kA/m (5 - 5) 0.001
  • frequency 50 Hz
  • polarisation 0,1 T to 1,9 T
817-MP-C604
Quantity: Soft magnetic sheet and powder materials: specific apparent power
Internal identifier Range Calibration and measurement capabilities Conditions of measurement Procedure Note to procedure
MAT11 (1 - 100) VA/kg (30 - 30) 0.001
  • frequency 50 Hz
  • polarisation 0,3 T to 1,7 T
817-MP-C604
Quantity: Soft magnetic bulk materials: magnetic saturation polarization
Internal identifier Range Calibration and measurement capabilities Procedure Note to procedure
MAT20 (0.2 - 5) Am2/kg (15 - 15) 0.001 817-MP-C606
Quantity: Hard magnetic materials: remanent magnetic flux density
Internal identifier Range Calibration and measurement capabilities Procedure Note to procedure
MAT23 (0.1 - 1.3) T (15 - 15) 0.001 817-MP-C605
Quantity: Hard magnetic materials: coercive field strength (HCB, HCJ)
Internal identifier Range Calibration and measurement capabilities Procedure Note to procedure
MAT24 (30 - 400) kA/m (15 - 15) 0.001 817-MP-C605
Quantity: Hard magnetic material: maximum energy product (B·H)max
Internal identifier Range Calibration and measurement capabilities Procedure Note to procedure
MAT25 (100 - 500) kJ/m3 (25 - 25) 0.001 817-MP-C605
Quantity: AC current
Internal identifier Range Calibration and measurement capabilities Procedure Note to procedure
9.20 (1 - 10) kA (0.021 - 0.1) % 817-MP-C705
9.20 (1 - 10) kA (5 - 20) ꞌ 817-MP-C705
9.20 (1 - 30) kA (0.021 - 0.1) % 817-MP-C705
9.20 (1 - 30) kA (5 - 20) ꞌ 817-MP-C705
Quantity: magnetic flux density
Internal identifier Range Calibration and measurement capabilities Procedure Note to procedure
(1 - 2000) mT (0.21 - 0.21) % 817-MP-C607
Quantity: electromagnetic fields above 50 kHz: AC magnetic flux density
Internal identifier Range Calibration and measurement capabilities Conditions of measurement Procedure Note to procedure
EMF14 (0.001 - 0.08) mT (20 - 20) 0.001
  • frequency 50 kHz to 100 kHz
817-MP-C608
Field of measurement: photometry and radiometry
Quantity: Luminous intensity
Internal identifier Range Calibration and measurement capabilities Conditions of measurement Procedure Note to procedure
(1 - 1.0E+4) cd (0.9 - 0.8) %
  • Correlated colour temperature (2000 up to 2856) K
818-MP-C811
(1 - 1.0E+4) cd (0.8 - 0.9) %
  • Correlated color temperature (2856 up to 3200) K
818-MP-C811
17 (1 - 2.0E+4) cd (0.8 - 0.8) % 818-MP-C811
Quantity: Illuminance responsivity, tungsten source
Internal identifier Range Calibration and measurement capabilities Conditions of measurement Procedure Note to procedure
(- - -) A/lx (0.9 - 0.8) %
  • Illuminance (0.1 up to 10) lx
  • Correlated colour temperature 2856 K
818-MP-C811
(- - -) A/lx (0.8 - 0.8) %
  • Illuminance (10 up to 1000) lx
  • Correlated colour temperature 2856 K
818-MP-C811
(- - -) A/lx (0,8 - 1,2) %
  • Illuminance (1000 up to 30000) lx
  • Correlated colour temperature 2856 K
818-MP-C811
Quantity: Luminous flux
Internal identifier Range Calibration and measurement capabilities Conditions of measurement Procedure Note to procedure
(10 - 3.0E+4) lm (0,9 - 1,5) %
  • Correlated colour temperature (2000 up to 3200) K
818-MP-C807
19 (10 - 2.0E+4) lm (1 - 1) % 818-MP-C807
Quantity: Illuminance
Internal identifier Range Calibration and measurement capabilities Conditions of measurement Procedure Note to procedure
(0.1 - 10) lx (0,9 - 0,8) %
  • Correlated colour temperature (2000 up to 3200) K
818-MP-C811
(10 - 1000) lx (0,8 - 0,8) %
  • Correlated colour temperature (2000 up to 3200) K
(1000 - 3.0E+4) lx (0,8 - 1,2) %
  • Correlated colour temperature (2000 up to 3200) K
818-MP-C811
6 (5 - 5.0E+4) lx (2.2 - 2.2) % 818-MP-C801
6 (1 - 5.0E+4) lx (0.8 - 0.8) % 818-MP-C811