You are here

CMC database

Field of measurement: electricity and magnetism
Quantity: antenna factor
Internal identifier Range Calibration and measurement capabilities Conditions of measurement Procedure Note to procedure
9.29 (-10 - 60) dB/m (1.5 - 1.5) dB
  • frequency 100 MHz up to 300 MHz
851-MP-C004 chapter 5.1 (ANSI C63.5, kap. 5)
9.29 (-10 - 60) dB/m (1.4 - 1.4) dB
  • frequency 300 MHz up to 1000 MHz
851-MP-C004 chapter 5.1 (ANSI C63.5, kap. 5)
9.29 (-10 - 60) dB/m (2 - 2) dB
  • frequency 1000 MHz up to 18000 MHz
851-MP-C004 chapter 5.1 (ANSI C63.5, kap. 5)
9.29 (-10 - 60) dB/m (3.3 - 3.3) dB
  • frequency 30 MHz up to 100 MHz
851-MP-C004 chapter 5.1 (ANSI C63.5, kap. 5)
9.29 (-10 - 60) dB/m (3.3 - 3.3) dB
  • frequency 100 MHz up to 300 MHz
851-MP-C004 chapter 5.1 (ANSI C63.5, kap. 5)
9.29 (-10 - 60) dB/m (3.5 - 3.5) dB
  • frequency 300 MHz up to 1000 MHz
851-MP-C004 chapter 5.1 (ANSI C63.5, kap. 5)
9.29 (-10 - 60) dB/m (2.2 - 2.2) dB
  • frequency 1000 MHz up to 18000 MHz
851-MP-C004 chapter 5.1 (ANSI C63.5, kap. 5)
9.29 (-10 - 60) dB/m (2.5 - 2.5) dB
  • frequency 30 MHz up to 100 MHz
851-MP-C004 chapter 5.1 (ANSI C63.5, kap. 5)
9.29 (-10 - 60) dB/m (1.7 - 1.7) dB
  • frequency 100 MHz up to 300 MHz
851-MP-C004 chapter 5.1 (ANSI C63.5, kap. 5)
9.29 (-10 - 60) dB/m (1.7 - 1.7) dB
  • frequency 300 MHz up to 1000 MHz
851-MP-C004 chapter 5.1 (ANSI C63.5, kap. 5)
9.29 (-10 - 60) dB/m (2.2 - 2.2) dB
  • frequency 1000 MHz up to 18000 MHz
851-MP-C004 chapter 5.1 (ANSI C63.5, kap. 5)
9.29 (-10 - 60) dB/m (2.1 - 2.1) dB
  • frequency 0,009 MHz up to 30 MHz
851-MP-C004 chapter 5.1 (ANSI C63.5, kap. 5)
9.29 (-10 - 60) dB/m (3.5 - 3.5) dB
  • frequency 30 MHz up to 1000 MHz
851-MP-C004 chapter 5.1 (ANSI C63.5, kap. 5)
9.29 (-10 - 60) dB/m (3.1 - 3.1) dB
  • frequency 1000 MHz up to 18000 MHz
851-MP-C004 chapter 5.1 (ANSI C63.5, kap. 5)
9.29 (-10 - 60) dB/m (2.2 - 2.2) dB
  • frequency 0,01 MHz up to 30 MHz
851-MP-C004 chapter 5.1 (ANSI C63.5, kap. 5)
Field of measurement: mass
Quantity: mass
Internal identifier Range Calibration and measurement capabilities Conditions of measurement Procedure Note to procedure
2 (0 - 20) kg (5.0E-7 - 5.0E-7) MH
  • weight E2 
612-MP-C132
2 (20 - 50) kg (1.6E-6 - 1.6E-6) MH
  • weight F1 
612-MP-C132
2 (50 - 600) kg (5.0E-6 - 5.0E-6) MH
  • weight F2 
612-MP-C132
2 (600 - 2.0E+5) kg (1.6E-5 - 1.6E-5) MH
  • weight M 
612-MP-C132
Field of measurement: hardness
Quantity: hardness Rockwell
Internal identifier Range Calibration and measurement capabilities Conditions of measurement Procedure Note to procedure
12 (10 - 100) HRA (0.38 - 0.38) HR
  • Rockwell A 
813-MP-C307 ČSN EN ISO 6508-2
12 (10 - 110) HRBW (0.38 - 0.38) HR
  • Rockwell B 
813-MP-C307 ČSN EN ISO 6508-2
12 (10 - 80) HRC (0.38 - 0.38) HR
  • Rockwell C 
813-MP-C307 ČSN EN ISO 6508-2
12 (10 - 90) HRD (0.38 - 0.38) HR
  • Rockwell D 
813-MP-C307 ČSN EN ISO 6508-2
12 (10 - 110) HREW (0.38 - 0.38) HR
  • Rockwell E 
813-MP-C307 ČSN EN ISO 6508-2
12 (10 - 100) HRFW (0.38 - 0.38) HR
  • Rockwell F 
813-MP-C307 ČSN EN ISO 6508-2
12 (10 - 100) HRGW (0.38 - 0.38) HR
  • Rockwell G 
813-MP-C307 ČSN EN ISO 6508-2
12 (10 - 110) HRHW (0.38 - 0.38) HR
  • Rockwell H 
813-MP-C307 ČSN EN ISO 6508-2
12 (6 - 110) HRKW (0.38 - 0.38) HR
  • Rockwell K 
813-MP-C307 ČSN EN ISO 6508-2
12 (10 - 100) HR15N (0.57 - 0.57) HR
  • Rockwell 15N 
813-MP-C307 ČSN EN ISO 6508-2
12 (10 - 100) HR30N (0.57 - 0.57) HR
  • Rockwell 30N 
813-MP-C307 ČSN EN ISO 6508-2
12 (10 - 90) HR45N (0.57 - 0.57) HR
  • Rockwell 45N 
813-MP-C307 ČSN EN ISO 6508-2
12 (10 - 100) HR15TW (0.57 - 0.57) HR
  • Rockwell 15T 
813-MP-C307 ČSN EN ISO 6508-2
12 (10 - 90) HR30TW (0.57 - 0.57) HR
  • Rockwell 30T 
813-MP-C307 ČSN EN ISO 6508-2
12 (6 - 80) HR45TW (0.57 - 0.57) HR
  • Rockwell 45T 
813-MP-C307 ČSN EN ISO 6508-2
Quantity: hardness Vickers
Internal identifier Range Calibration and measurement capabilities Conditions of measurement Procedure Note to procedure
12 (20 - 225) HV (0.32 - 0.32) % HV
  • Vickers 
813-MP-C307 ČSN EN ISO 6508-2
12 (225 - 700) HV (0.32 - 0.32) % HV
  • Vickers 
813-MP-C307 ČSN EN ISO 6508-2
12 (700 - 3000) HV (0.32 - 0.32) % HV
  • Vickers 
813-MP-C307 ČSN EN ISO 6508-2
Quantity: tvrdost Brinell
Internal identifier Range Calibration and measurement capabilities Conditions of measurement Procedure Note to procedure
12 (20 - 200) HBW (0.3 - 0.3) % HBW
  • Brinell 
813-MP-C307 ČSN EN ISO 6508-2
12 (200 - 500) HBW (0.3 - 0.3) % HBW
  • Brinell 
813-MP-C307 ČSN EN ISO 6508-2
12 (500 - 650) HBW (0.3 - 0.3) % HBW
  • Brinell 
813-MP-C307 ČSN EN ISO 6508-2
Field of measurement: metrology in chemistry
Quantity: Relative moisture
Internal identifier Range Calibration and measurement capabilities Analyt nebo komponenta Procedure Note to procedure
4 - 50 % 0.25 - 0.25% cereal seeds 511-MP-C001
4 - 50 % 0.27 - 0.27% cereals seeds 511-MP-C001
Quantity: Content of nitrogen substances
Internal identifier Range Calibration and measurement capabilities Analyt nebo komponenta Procedure Note to procedure
5 - 40 % 0.3 - 0.3% cereals seeds 511-MP-C001
Quantity: Oil content
Internal identifier Range Calibration and measurement capabilities Analyt nebo komponenta Procedure Note to procedure
10 - 80 % 0.29 - 0.29% cereals seeds 511-MP-C001
Quantity: Volume
Internal identifier Range Calibration and measurement capabilities Analyt nebo komponenta Procedure Note to procedure
10 - 75 ml 1.3 - 1.3ml cereals seeds 511-MP-C001
Quantity: Absolute moisture
Internal identifier Range Calibration and measurement capabilities Analyt nebo komponenta Procedure Note to procedure
4 - 110 % 0.31 - 0.31% wood 511-MP-C003