You are here

CMC database

Field of measurement: electricity and magnetism
Quantity: hf power
Internal identifier Range Calibration and measurement capabilities Conditions of measurement Procedure Note to procedure
9.28 (20 - -20) dBm (0.17 - 0.17) dB
  • frequency 0,1 MHz up to 6 GHz
113-MP-C014
9.28 (-20 - -60) dBm (0.22 - 0.22) dB
  • frequency 0,1 MHz up to 6 GHz
113-MP-C014
Quantity: hf power ratio (attenuation, gain)
Internal identifier Range Calibration and measurement capabilities Conditions of measurement Procedure Note to procedure
9.26 (0 - 55) dB (0,015+0,0005 MH - 0,015+0,0005 MH) dB
  • frequency 0,1 MHz up to 26,5 GHz
113-MP-C014
9.26 (55 - 75) dB (0,046+0,0005 MH - 0,046+0,0005 MH) dB
  • frequency 0,1 MHz up to 26,5 GHz
113-MP-C014
9.26 (75 - 90) dB (0,12+0,0047 (MH-75) - 0,12+0,0047 (MH-75)) dB
  • frequency 0,1 MHz up to 18 GHz
113-MP-C014
9.26 (75 - 90) dB (0,12+0,019 (MH-75) - 0,12+0,019 (MH-75)) dB
  • frequency 18 GHz up to 26,5 GHz
113-MP-C014
9.26 (90 - 100) dB (0,12+0,012 (MH-90) - 0,12+0,012 (MH-90)) dB
  • frequency 0,1 MHz up to 13,2 GHz
113-MP-C014
9.26 (0 - 40) dB (0.1 - 0.1) dB
  • frequency 26,5 GHz up to 40 GHz
113-MP-C014
Quantity: antenna factor
Internal identifier Range Calibration and measurement capabilities Conditions of measurement Procedure Note to procedure
(-60 - 90) dB (0.14 - 1) dB
  • frequency 10 Hz to 30 MHz
113-MP-C016
Field of measurement: time and frequency
Quantity: frequency
Internal identifier Range Calibration and measurement capabilities Procedure Note to procedure
12.1a (0.01 - 3.0E+9) Hz (1.0E-11 - 1.0E-11) 113-MP-C007
12.1b (3 - 18) GHz (1 - 1) Hz 113-MP-C007
12.1c (18 - 46) GHz (3 - 3) Hz 113-MP-C007
Quantity: period
Internal identifier Range Calibration and measurement capabilities Procedure Note to procedure
12.2 (5.0E-9 - 1.0E+5) s (1.0E-11 - 1.0E-11) 113-MP-C007
Quantity: time interval
Internal identifier Range Calibration and measurement capabilities Procedure Note to procedure
12.3 (0 - 1.0E+5) s (1,1×10-9 + 1×10-11 t - 1,1×10-9 + 1×10-11 t) s 113-MP-C007
12.3 (0 - 10) s (10×10-12 + 2×10-3 t - 10×10-12 + 2×10-3 t ) s 113-MP-C007
Quantity: pulse counting, fmax=50 MHz
Internal identifier Range Calibration and measurement capabilities Procedure Note to procedure
12.4 (0 - 1.0E+7) s 0 113-MP-C007
Quantity: FM frequency deviation, fc=250 kHz up to 10 MHz, fmod: 20 Hz up to 10 kHz, Df/fmod ˃ 0,2
Internal identifier Range Calibration and measurement capabilities Procedure Note to procedure
12.5 (0.2 - 40) kHz (1.5 - 1.5) % 113-MP-C007
Quantity: FM frequency deviation, fc=250 kHz up to 10 MHz, fmod: 20 Hz up to 10 kHz, Df/fmod ˃ 1,2
Internal identifier Range Calibration and measurement capabilities Procedure Note to procedure
12.5 (0.2 - 40) kHz (1 - 1) % 113-MP-C007
Quantity: FM frequency deviation, fc=10 MHz up to 6,6 GHz, fmod: 50 Hz up to 200 kHz, Df/fmod ˃ 0,2
Internal identifier Range Calibration and measurement capabilities Procedure Note to procedure
12.5 (0.25 - 400) kHz (1.5 - 1.5) % 113-MP-C007
Quantity: FM frequency deviation, fc=10 MHz up to 6,6 GHz, fmod: 50 Hz up to 200 kHz, Df/fmod ˃ 0,45
Internal identifier Range Calibration and measurement capabilities Procedure Note to procedure
12.5 (0.25 - 400) kHz (1 - 1) % 113-MP-C007
Field of measurement: metrology in chemistry
Quantity: Concentration
Internal identifier Range Calibration and measurement capabilities Analyt nebo komponenta Matrice Procedure Note to procedure
0.14 - 0.14 mg.l-1 0.006 - 0.006mg.l-1 ethanol in the gas phase 114-MP-C004
0.48 - 0.48 mg.l-1 0.011 - 0.011mg.l-1 ethanol in the gas phase 114-MP-C004
0.9 - 0.9 mg.l-1 0.019 - 0.019mg.l-1 ethanol in the gas phase 114-MP-C004
1.4 - 1.4 mg.l-1 0.028 - 0.028mg.l-1 ethanol in the gas phase 114-MP-C004
0.14 - 0.14 mg.l-1 0.008 - 0.008mg.l-1 ethanol in the gas phase 114-MP-C004
Field of measurement: ionising radiation
Quantity:
Internal identifier Range Calibration and measurement capabilities Conditions of measurement Procedure Note to procedure
EUR-RAD-CMI-2001 (1 - 100) Bq.cm-2 3.6 %
  • C-14 rectangular, 110 mm x 150 mm, or circular, diameter 23 mm to 45 mm
911-MP-C007
EUR-RAD-CMI-2002 (10 - 100) Bq.cm-2 3.2 %
  • Co-60 rectangular, 110 mm x 150 mm, or circular, diameter 23 mm to 45 mm
911-MP-C007
EUR-RAD-CMI-2003 (10 - 100) Bq.cm-2 3.2 %
  • Sr-90 rectangular, 110 mm x 150 mm, or circular, diameter 23 mm to 45 mm
911-MP-C007
EUR-RAD-CMI-2004 (10 - 100) Bq.cm-2 3.2 %
  • Cs-137 rectangular, 110 mm x 150 mm, or circular, diameter 23 mm to 45 mm
911-MP-C007
EUR-RAD-CMI-2005 (10 - 100) Bq.cm-2 3.2 %
  • Pm-147 rectangular, 110 mm x 150 mm, or circular, diameter 23 mm to 45 mm
911-MP-C007
EUR-RAD-CMI-2006 (10 - 100) Bq.cm-2 3.6 %
  • Tl-204 rectangular, 110 mm x 150 mm, or circular, diameter 23 mm to 45 mm
911-MP-C007
EUR-RAD-CMI-2007 (1 - 10) Bq.cm-2 3.6 %
  • Pu-239 rectangular, 110 mm x 150 mm, or circular, diameter 23 mm to 45 mm
911-MP-C007
EUR-RAD-CMI-2008 (1 - 10) Bq.cm-2 3.6 %
  • Am-241 rectangular, 110 mm x 150 mm, or circular, diameter 23 mm to 45 mm
911-MP-C007
EUR-RAD-CMI-2009 (1 - 5) Bq.cm-2 4 %
  • U-nat rectangular, 110 mm x 150 mm, or circular, diameter 23 mm to 45 mm
911-MP-C007
EUR-RAD-CMI-2010 (0 - 1) s-1.Bq-1 10 %
  • C-14 detection beta radiation
911-MP-C007
EUR-RAD-CMI-2011 (0 - 1) s-1.Bq-1 10 %
  • Cs-137 detection beta radiation
911-MP-C007
EUR-RAD-CMI-2012 (0 - 1) s-1.Bq-1 10 %
  • Sr-90 detection beta radiation
911-MP-C007
EUR-RAD-CMI-2013 (0 - 1) s-1.Bq-1 10 %
  • Am-241 detection alpha radiation
911-MP-C007
EUR-RAD-CMI-2014 (5000 - 5.0E+7) Bq.g-1 4 %
  • H-3 tritiated water
911-MP-C007
EUR-RAD-CMI-2015 (5000 - 5.0E+7) Bq.g-1 2 %
  • Be-7 glass ampoule
911-MP-C007
EUR-RAD-CMI-2016 (5000 - 5.0E+7) Bq.g-1 3 %
  • C-14 glass ampoule
911-MP-C007
EUR-RAD-CMI-2017 (5000 - 5.0E+7) Bq.g-1 1.6 %
  • Na-22 glass ampoule
911-MP-C007
EUR-RAD-CMI-2018 (5000 - 5.0E+7) Bq.g-1 1.2 %
  • Na-24 glass ampoule
911-MP-C007
EUR-RAD-CMI-2019 (5000 - 5.0E+7) Bq.g-1 1.2 %
  • P-32 glass ampoule
911-MP-C007
EUR-RAD-CMI-2020 (5000 - 5.0E+7) Bq.g-1 2.6 %
  • S-35 glass ampoule
911-MP-C007
EUR-RAD-CMI-2021 (5000 - 5.0E+7) Bq.g-1 1.2 %
  • K-42 glass ampoule
911-MP-C007
EUR-RAD-CMI-2022 (5000 - 5.0E+7) Bq.g-1 2.4 %
  • Ca-45 glass ampoule
911-MP-C007
EUR-RAD-CMI-2023 (5000 - 5.0E+7) Bq.g-1 1.6 %
  • Cr-51 glass ampoule
911-MP-C007
EUR-RAD-CMI-2024 (5000 - 5.0E+7) Bq.g-1 1.2 %
  • Mn-54 glass ampoule
911-MP-C007
EUR-RAD-CMI-2025 (5000 - 5.0E+7) Bq.g-1 5.5 %
  • Fe-55 glass ampoule
911-MP-C007

Pages