Field of measurement

Interní identifikátor

CZ13

Quantity

Instrument or artifact

Calibration and measurement capabilities

Range Calibration and measurement capabilities
0.002 - 10 m3/h 0,25 % (2-5)L/h; 0,16 for (5-12)L/h; 0,09 for (12-25)L/h; 0,07 for (25-50)L/h; 0,05 for (50-10000) L/h %

Technical competence

Measurement conditions

fluid water
temperature (10-50) ºC
pressure (0,03-1,6) MPa
pipe size DN6 -DN32

Method

Number of procedure Title of procedure
Calibration and verification of water meters, flow sensors of heat meters and flow meters by water